Download this
document in: Word
Format PDF
Format
Deco-Pour Terrazzo & Decorative
Overlayment Section 03300 - HDS 2001 Spray Applied
System
This specification is provided by Deco-Pour as a service
and is intended to be used as a guideline for preparing the
appropriate project specific specification sections. Every
heading may not be needed. Delete heading not used and
renumber remaining used headings to be numerically correct.
PART 1 GENERAL
- 1.01 SUMMARY
- This section
includes the following.
- Application of the Deco-Pour HDS product.
- Related Work:
- Section 03300 Cast-In-Place Concrete/New
Construction Vapor Emission
- Section 09400 Polished Decorative Overlayments
- 1.02 REFERENCES
- American Society
for Testing and Materials:
- AASHTO T—277-89, Rapid Chloride Permeability ASTM
C-23-69 Artificial Weathering
- ASTM C-67, Section 7, Water Absorption ASTM-67,
Section 10, Efflorescence
- ASTM C-51 8, Thermal Conductivity and Thermal
Resistance
- ASTM C-666, Freeze-Thaw Resistance & Resistance
to Salt Attack
- DIN 1048 (German Industry Norm/Standard)
Waterproofing against Hydrostatic Pressure of 7
Bar-101.5 PSI – 234.5 Ft. Water
- DIN 1048 Resistance to De-Icing Salts, Chemical
Attack and Freeze-Thaw Damage Authorized by USDA for use
in Meat and Poultry Plants.
- EPA Approved for Potable Water
- 1.03 SUBMITTALS
- Comply with
pertinent provisions of Section 01600-Product
Requirements.
- Provide submittal information within 35 calendar
days after the contractor has received the owner’s
notice to proceed.
- Product data:
- Submit special concrete finishes manufacturer’s
Material Safety Data Sheet (MSDS) and other safety
requirements.
- Follow all special concrete finishes published
manufacturer’s installation instructions.
- Test Reports:
- Provide certified test reports, prepared by an
independent testing laboratory, confirming compliance
with specified performance criteria.
- 1.04 QUALITY ASSURANCE
- Installer
Qualifications:
- A Deco-Pour technician will be on site the day of
the concrete pour to train in application, returning on
every application thereafter to verify application for
technician services.
- Use an experienced installer and adequate number of
skilled workmen who are thoroughly trained and
experienced in the necessary craft.
- The special concrete finish manufacturer shall
certify applicator.
- Applicator shall be familiar with the specified
requirements and the methods needed for proper
performance of work of the section.
- Manufacturer’s Certification:
- Provide letter of certification from concrete finish
manufacturer stating that installer is certified
applicator of special concrete finishes, and is familiar
with proper procedures and installation requirements
required by the manufacturer.
- Protection:
- No satisfactory chemical or cleaning procedure is
available to remove petroleum stains from the concrete
surface. Prevention is therefore essential.
- All hydraulic powered equipment must be diapered
to avoid staining of the concrete.
- No trade will park vehicles on the inside slab. If
necessary to complete their scope of work, drop cloths
will be placed under vehicles at all times.
- No pipe cutting machine will be used on the
concrete floor slab.
- Steel will not be placed on slab to avoid rust
staining.
- Acids and acidic detergents will not come into
contact with slab.
- All trades informed that the slab must be
protected at all times.
- 1.05 DELIVERY, STORAGE AND
HANDLING
- Deliver material in original containers, with seal’s
unbroken, bearing manufacturer labels indicating brand
name and direction for storage.
- Dispense special concrete finish material from factory
numbered and sealed containers. Maintain record of
container numbers.
- 1.06 PROJECT CONDITIONS
- Environmental limitations:
- Comply with manufacturers written instructions for
substrate temperature and moisture content, ambient
temperature and humidity, ventilation, and other
conditions affecting topping performance.
- Close areas to traffic during floor application and
after application, for time period recommended in writing
by manufacturer.
PART 2 PRODUCTS
- 2.01 MATERIAL AND MANUFACTURERS
- Deco-Pour
Sealer/Hardener/Curing Compound
- Manufactured by Deco-Pour, 13614 SR9 SE, Snohomish,
Washington 98296, 1.360.668.2218
- ASTM C1315 Type 1 Class A
- ASTM C309 Type 1, Class A
- Penetrating product to have no less than 34% solids
content.
- Volatile organic compound (VOC) content rating as
required to suit regulatory requirements.
- 2.02 RELATED MATERIALS
PART
3-EXECUTION
- 3.01 SURFACE CONDITIONS
- Follow all
specification for ground preparation, reinforcing, design
mix and admix specifications, etc..
- After pouring, placing, bullfloating, final broom
finish, and the surface of the concrete has hardened
sufficiently to sustain foot traffic, HDS 2001-A Sealer
may be applied.
- 3.02 APPLICATION
- Start any of the
floor finish applications in presence of manufacturer’s
technical representative. Manufacture technician will be
on site the day of the concrete pour to train in
application, returning on every application thereafter to
verify correct application at no charge for technical
services
- Sealing, hardening and polishing Concrete Surface.
- Spray apply HDS 2001-A at the rate of 200 square
feet per gallon. If puddling or bird bathing occurs,
lightly broom product evenly over the substrate.
- Re-apply product to areas subject to heavy rainfall
within 2 hours after initial application.
- 3.03 WORKMANSHIP AND CLEANING:
- The premises
shall be kept clean and free of debris at all times.
- Remove spatter from adjoining surfaces, as necessary.
- Remove debris from jobsite
- 3.04 PROTECTION
- Protect finished
work until fully cured in accordance with manufacturer’s
recommendations.
Download this document in: Word
Format PDF
Format |